| General | 
| Power Requirements | 12 V DC (10.8 V to 13.2 V) | 
| PoE+ | IEEE802.3at standard: DC 42 V to 57 V (Camera Input) | 
| Current Consumption | 1.0 A (Connector Input) 0.6 A (PoE+ power supply)
 | 
| Ambient Operating Temperature | : 0 °C to 40 °C (32 °F to 104 °F) | 
| Allowable Humidity | 20% to 90% (no condensation) | 
| Storage Temperature | –20 °C to 50 °C (–4 °F to 122 °F) | 
| Weight | Approx. 3.2 kg (7.05 lb) | 
| Dimensions (W x H x D) | 342 mm x 178 mm x 245 mm (13-15/32 inches x 7 inches x 9-21/32 inches) (excluding protrusions)
 | 
| Connection Supported
 Equipment
 | IP/RS422 AW-UE150W/K
 AW-HR140
 AW-HE130W/K
 AW-HN130W/K
 AW-UE70W/K
 AW-UN70W/K
 AW-HE40 Series
 AW-HN40HW/HK
 AW-HE38HW/HK
 AW-HN38HW/HK
 | 
| Input/Output Connectors | 
| Input: DC 12 V IN | XLR 4-pin | 
| Input: 3G-SDI IN | SMPTE292 / 75 Ω (BNC x 1) Supported formats:
 1080/59.94p*2, 1080/50p*2,
 1080/59.94i, 1080/50i, 1080/23.98p,
 1080/25p, 1080/23.98PsF, 1080/25PsF
 | 
| Output: ACTIVE THRU OUT | SMPTE292 / 75 Ω (BNC x 1) | 
| Input/Output: IP CONT | 100BASE-TX PoE+ input
 Connection cable: LAN cable, max. 100 m (328 ft)
 • When connecting the unit via a switching hub:
 Straight cable or a cross cable (category 5 cable), STP (Shielded
 Twisted Pair) cable recommended
 • When connecting the unit directly: Crossover cable (category 5
 cable), STP (Shielded Twisted Pair) cable recommended
 | 
| Input/Output: SERIAL CONT (RJ-45) | RS-422 (control signals for remote cameras), TALLY OUT Connecting cable:
 Straight cable (category 5e or better shielded cable),
 max. 1000 m (3280 ft)
 TALLY OUT: Open collector output (negative logic)
 Maximum voltage resistance DC 24 V, Maximum current 50 mA
 | 
| Input/Output: TALLY/GPIO 1 | D-sub 25-pin, female, inch thread TALLY IN : 10 inputs (for receiving photocoupler signals)
 GPI : 6 inputs (for receiving photocoupler signals)
 GPIO : 5 inputs (for receiving photocoupler signals)
 or 5 outputs (open collector outputs, negative logic)
 • Input/output switched with menu settings
 | 
| Input/Output: GPIO 2 | D-sub 25-pin, female, inch thread GPI : 10 inputs (for receiving photocoupler signals)
 GPIO : 10 inputs (for receiving photocoupler signals)
 or 10 outputs (open collector outputs, negative logic)
 • Input/output switched with menu settings
 Reserve connectors:
 2 connectors (For future expansion feature)
 | 
| LCD Display | 7-inch Touch Panel GUI Monitor (WVGA (800×480)) | 
| SD Memory Card Slot | SDHC / SDXC Memory Card Slot x 1 | 
| Connection Specifications | 
| No. of Connectable Cameras | 200 (IP), 5 (RS422) | 
| No. of Camera Selection Buttons | 10 | 
| No. of Camera Groups | 20 (10 units per 1 group) | 
| Memory | 
| Preset Memory | No. of memory presets: 100 | 
| Tracing Memory: No. of cameras |  | 
| Tracing Memory: Recording time, no. of memory settings | Maximum 5 min. total per camera, maximum of 10 settings per camera | 
| Other Functions | 
| No. of User Assignable Buttons | 6 + up to 10 on the LCD menu | 
| Pan / Tilt Speed Adjustment | 7 levels | 
| Tally LED Display Color | green / red |